Test results test_can_rxconv.A_TEMP.TEMP_EX

Package: EDC17_120713
Test variant: FA_CAN_110713
Date: 12.07.2013

Variable check

Test NameDescriptionState
CAN signal'TEMP_EX' available in Inca.PASSED
ECU internal variable'Com_tEnvT_FA' available in Inca.PASSED

Test preconditions

Resolution checkState
ECU internal resolution (Com_tEnvT_FA=0.5) is equal or higher than bus resolution (TEMP_EX=0.5)PASSED

Physical unit checkState
Bus signal physical unit (°C)
ECU internal physical unit (Grad C)
INFO

Check signal conversion
FlexRay signal - bus name: TEMP_EX
FlexRay signal - Inca name: TEMP_EX
ECU internal variable - name: Com_tEnvT_FA
Allowed absolute deviation (phys): 0.5

Bus SignalBus ValueECU VariableECU ValueDeviationState
TEMP_EX-40Com_tEnvT_FA-38.51.5CONVERSION FAILED
TEMP_EX-39.5Com_tEnvT_FA-38.51CONVERSION FAILED
TEMP_EX22Com_tEnvT_FA-38.560.5CONVERSION FAILED
TEMP_EX83.5Com_tEnvT_FA-38.5122CONVERSION FAILED
TEMP_EX84.5Com_tEnvT_FA-38.5123CONVERSION FAILED
TEMP_EX85Com_tEnvT_FA-38.5123.5CONVERSION FAILED


Generated by loghtml.pm v1.1.0 on 12.07.2013 13:50:21