Test results test_can_rxconv.DT_DISP_GRDT.DISP_RQ_GR_GRB

Package: 20B5_0000208D_159_010_001_FA_CAN
Test variant: FA_CAN
Date: 07.08.2013

Variable check

Test NameDescriptionState
CAN signal'DISP_RQ_GR_GRB' available in Inca.PASSED
ECU internal variable'Com_FA_DispRqGrGrb' available in Inca.PASSED

Test preconditions

Resolution checkState
ECU internal resolution (Com_FA_DispRqGrGrb=1) is equal or higher than bus resolution (DISP_RQ_GR_GRB=1)PASSED

Physical unit checkState
No physical units givenINFO

Check signal conversion
FlexRay signal - bus name: DISP_RQ_GR_GRB
FlexRay signal - Inca name: DISP_RQ_GR_GRB
ECU internal variable - name: Com_FA_DispRqGrGrb
Allowed absolute deviation (phys): 1

Bus SignalBus ValueECU VariableECU ValueDeviationState
DISP_RQ_GR_GRB0Com_FA_DispRqGrGrb00PASSED
DISP_RQ_GR_GRB1Com_FA_DispRqGrGrb10PASSED
DISP_RQ_GR_GRB7Com_FA_DispRqGrGrb16CONVERSION FAILED
DISP_RQ_GR_GRB13Com_FA_DispRqGrGrb112CONVERSION FAILED
DISP_RQ_GR_GRB14Com_FA_DispRqGrGrb140PASSED
DISP_RQ_GR_GRB15Com_FA_DispRqGrGrb150PASSED


Generated by loghtml.pm v1.1.0 on 07.08.2013 13:34:31